GENERAL DATA
Electrical | ||
Operating frequency |
9410 ± 30 MHz | |
Cathode |
indirectly heated | |
Heater voltage (see note 1) |
6.3 |
V |
Heater current at 6.3V |
0.5 |
A |
Cathode pre-heating time |
30 |
s |
Input capacitance |
8.0 |
pF max |
Mechanical | |
Output |
no.16 wave guide |
Overall dimensions |
see Outline |
Net weight |
250g approx |
Mounting position |
any |
Coupler |
IEC UBR 100 |
Cooling |
natural |
Magnet |
integral |
A minimum clearance of 5 mm must be |
NOTES
1. No reduction of heater voltage is required at any value of mean input power.For optimum performance a value within the specified ratings must be maintained.
The magnetron heater must be protected against arcing by the use of a minimum
capacitance of 4000 pF shunted across the heater directly at the input terminals;
in some cases a capacitance as high as 2mF may be necessary depending on the
equipment design. For further details see the Magnetron Preamble.
2. Measured with heater voltage of 6.3 V and no anode input power, the heater
current limits are 0.5 A minimum, 0.6 A maximum.
3. For ambient temperatures above 0 ℃. For ambient temperatures between
0 and -55 ℃, cathode pre-heating time is 75 seconds minimum.
OUTLINE (Not for inspection purposes)
(All dimensions without limits are nominal)