본문 바로가기
Marine Radar Parts/Magnetron

MG4004 X-Band Magnetron

by 얼라이드이파트 2012. 6. 28.

 

 

GENERAL DATA

Electrical

 Operating frequency

9410 ± 30 MHz 

Cathode

indirectly heated

Heater voltage (see note 1)

6.3

V

Heater current at 6.3V
(see note 2)

0.5

A

Cathode pre-heating time
(minimum) (see note 3)

30

s

Input capacitance

8.0

pF max

Mechanical

Output

no.16 wave guide

Overall dimensions

see Outline

Net weight

250g approx

Mounting position

any

Coupler

IEC UBR 100

Cooling

natural

Magnet

integral

A minimum clearance of 5 mm must be
maintained between the magnetron and
any magnetic materials.

NOTES

1. No reduction of heater voltage is required at any value of mean input power.
  For optimum performance a value within the specified ratings must be maintained.
  The magnetron heater must be protected against arcing by the use of a minimum
  capacitance of 4000 pF shunted across the heater directly at the input terminals;
  in some cases a capacitance as high as 2mF may be necessary depending on the
  equipment design. For further details see the Magnetron Preamble.


2. Measured with heater voltage of 6.3 V and no anode input power, the heater
  current limits are 0.5 A minimum, 0.6 A maximum.


3. For ambient temperatures above 0 ℃. For ambient temperatures between
  0 and -55 ℃, cathode pre-heating time is 75 seconds minimum.

 

OUTLINE (Not for inspection purposes)