ABRIDGED DATA | |||||
Fixed frequency pulse magnetron. It is an improved version of the | |||||
Operating frequency |
3050 ± 25 |
MHz | |||
Typical peak output power |
56 |
kW | |||
Output |
probe radiating into waveguide launching section | ||||
Magnet |
integral | ||||
Launching section |
not supplied | ||||
Electrical |
Mechanical | ||||
Cathode |
indirectly heated |
Overall dimensions |
see outline | ||
Heater voltage (see note 1) |
6.3 |
V |
Netweight |
1.7 kg approx | |
Heater current at 6.3V |
1.25 |
A |
Mounting position |
any | |
Cathode pre-heating time |
3.0 |
min |
Cooling(see note 2) |
natural or forced-air | |
Heater starting current, peak value, |
6.0 |
A max |
A minimum clearance of 50 mm must be maintained between |
NOTES
1. With no anode input power.
On the application of anode power, the heater voltage must be reduced as follows:
Mean input power Heater voltage
(W) (Vrms)
less than 25 6.3
25 to 62 5.3
62 to 100 4.5
The magnetron heater must be protected against arcing by the use of a minimum capacitance of 4000 pF shunted across
the heater directly at the input terminals; in some cases a capacitance as high as 2 mF may be necessary depending
on the equipment design. For further details see the Magnetron Preamble.
2. The anode temperature must be kept below the limit specified by means of a suitable flow of air over the anode body.
OUTLINE (All dimensions without limits are nominal)