GENERAL DATA
Electrical | ||
Operating frequency |
9410 +- 30 |
MHz |
Typical peak outputcpower |
25 |
kW |
Cathode |
indirectly heated | |
Heater voltage (see note 1) |
6.3 |
V |
Heater current at 6.3V (see note 2) |
0.5 |
A |
Cathode pre-heating time |
60 |
s |
Input capacitance |
9.0 |
pFmax |
Temperature |
see note 4 |
Mechanical | |
Overall dimensions |
see Outline |
Net weight |
2.1 kg approx |
Mounting position |
any |
Coupler |
IEC UBR100 |
Cooling |
natural |
Magnet |
integral |
Output |
no.16waveguide |
A minimum clearance of 25 mm must be maintained between |
Notes
1. For optimum performance a value of 6.3 V is recommended. However, this magnetron will work
satisfactorily within the specified limits.
The magnetron heater must be protected against arcing by the use of a minimum capacitance of
4000 pF shunted across the heater directly at the input terminals;
in some cases a capacitance as high as 2 mF may be necessary depending on the equipment
design. For further details see the Magnetron Preamble.
2. Measured with heater voltage of 6.3 V and no anode input power, the heater current limits are 0.5 A
minimum, 0.6 A maximum.
3. For ambient temperatures above 0 8C. For ambient temperatures between 0 and 755 8C, cathode
pre-heating time is 90 seconds minimum.
4. Design test only. The maximum frequency change with anode temperature change (after warming) is
70.25 MHz/8C.
OUTLINE DIMENSIONS
Outline Notes
1. The mating surface of the magnetron baseplate will be flat to within 0.20 mm.
2. Positional tolerance of holes +0.2 mm with respect to waveguide aperture.
NJRC M1568B(S)(J)를 대체하여 사용하실수 있습니다.