GENERAL DATA
Electrical |
Mechanical | |||
Operating frequency |
9375 ±30 |
MHz |
Overall dimensions |
see Outline |
Typical peak |
25 |
kW |
Net weight |
0.7 kg approx |
Cathode |
indirectly heated |
Mounting position |
any | |
Heater voltage |
6.3 |
V |
Coupler |
IEC UBR100 |
Heater current at 6.3V (see note 2) |
0.5 |
A |
Cooling |
natural |
Cathode pre-heating time |
60 |
s |
Output |
no.16 waveguide |
Input capacitance |
9.0 |
pFmax |
Magnet |
integral |
Temperature coefficient of frequency |
see note 4 |
A minimum clearance of 25 mm must be maintained between | ||
Notes
1. For optimum performance a value of 6.3 V is recommended. However, this magnetron
will work satisfactorily within the specified limits.
The magnetron heater must be protected against arcing by the use of a minimum
capacitance of 4000 pF shunted across the heater directly at the input terminals;
in some cases a capacitance as high as 2mF may be necessary depending on the
equipment design. For further details see the Magnetron Preamble.
2. Measured with heater voltage of 6.3 V and no anode input power, the heater
current limits are 0.5 A minimum, 0.6 A maximum.
3. For ambient temperatures above 0 ℃. For ambient temperatures between
0 and -55 ℃, cathode pre-heating time is 45 seconds minimum.
4. Design test only. The maximum frequency change with
anode temperature change (after warming) is -0.25 MHz/℃.