| Electrical | Mechanical | |||
| Operating frequency | 9410 ±30 | MHz | Overall dimensions | see Outline | 
| Typical peak | 6.0 | kW | Net weight | 0.5 kg approx | 
| Cathode | indirectly heated | Mounting position | any | |
| Heater voltage | 6.3 | V | Coupler | IEC UBR100 | 
| Heater current at 6.3V (see note 2) | 0.55 | A | Cooling | natural | 
| Cathode | 60 | s | Output | no.16waveguide | 
| Cold impedance | see note 4 | A minimum clearance of 25 mm must be maintained between | ||
| Input capacitance | 8.0 | pFmax | ||
| Temperature  | see note 5 | |||
Notes
1. No reduction of heater voltage is required at any value of mean input power.
For optimum performance a value within the specified ratings must be maintained.
The magnetron heater must be protected against arcing by the use of a minimum 
capacitance of 4000 pF shunted across the heater directly at the input terminals;
in some cases a capacitance as high as 2mF may be necessary depending on the 
equipment design. For further details see the Magnetron Preamble. 
2. Measured with heater voltage of 6.3 V and no anode input power, the heater 
current limits are 0.5 A minimum, 0.6 A maximum.
3. For ambient temperatures above 0 ℃. For ambient temperatures between
0 and -55 ℃, cathode pre-heating time is 45 seconds minimum.
4. The impedance of the magnetron measured at the operating frequency when not oscillating
will be such as to give a v.s.w.r. of at least 6:1, with a voltage minimum 16.5 to
22.5 mm from the output flange toward the anode.
5. Design test only. The maximum frequency change with
anode temperature change (after warming) is -0.25 MHz/℃. 
OUT LINE
(All dimensions without limits are nominal)