본문 바로가기
Marine Radar Parts/Magnetron

MG5244 X-Band Magnetron

by 얼라이드이파트 2012. 6. 27.

 

ABRIDGED DATA

rugged, lightweight, fixed frequency pulse magnetron,

Operating frequency

9375 ± 30

MHz

Typical peak output power

12.5

kW

Magnet integral

Out put

No.16 waveguide(0.900x0.400 inch internal)

Coupler

IEC UBR100

Electrical

Mechanical

Cathode

indirectly heated

Overall dimensions

see outline

Heater voltage (see note 1)

6.3

V

Netweight

0.7 kg approx

Heater current at 6.3V

0.5

A

Mounting position

any

Cathode pre-heating time
(minimum)(see note 2)

30

s

Cooling

natural

Input capacitance

8.0

pF max

A minimum clearance of 25mm must be maintained between the magnetron and any magnetic materials.

 

NOTES

1. No reduction of heater voltage is required at any value of mean input power. For optimum performance 

  a value within the specified ratings must be maintained.
  The magnetron heater must be protected against arcing by the use of a minimum capacitance of 4000 pF 

  shunted across the heater directly at the input terminals; in some cases a capacitance as high as 2 mF

  may be necessary depending on the equipment design. For further details see the Magnetron Preamble.

 

2. For ambient temperatures above 0℃. For ambient temperatures between 0 and -55℃, cathode pre-

   heating time is 45 seconds minimum.

 

OUTLINE DIMENSIONS

OUTLINE NOTE

1. Anode temperature measured at this point.
2. Recommended direction of cooling air flow.
3. Reference plane B passes throught the centres of two mounting plate hole as shown and is

  perpendicular to plane A.
4. Reference plane C intersects plane B at the centres of the mounting plate hole as shown and is

  perpendicular to plane A and B.
5. With surface A resting on a flat surface plate, a feeler gauge 0.020 inch (0.51mm) thick and

  0.125 inch (3.18mm) wide will not enter more than 0.125 inch (3.18mm) at any point.
6. Holes will lie within 0.005 inch (0.127mm) of indicated centres: a cylinder 0.330 inch (8.38mm)

  diameter, centred in holes shown, will clear the side of the magnet.
7. The centre of this hole will be within 0.004 inch (0.102mm) of reference plane C.
8. Holes will lie within 0.015 inch (0.38mm) of indicated centres.
9. The position of the waveguide hole is not specified on this drawing since Tubes are tested and

  used into coupler IEC URB100. 10. The axis of the filament lead protector will be within 5℃ of a

  normal to Reference plane C.
11. The heater lead protector should not be used to support any cap fitting.

  This protector is a detachable sleeve of a non-conducting material.
12. The clearance between the inside surface of the protector and the 0.375 Inch (9.53mm) diameter

  cylindrical surface of the standard single contact miniature lamp base will not be less than 0.157 inch

  (3.99mm).

'Marine Radar Parts > Magnetron' 카테고리의 다른 글

9M302(->MG4004) X-Band Magnetron  (0) 2012.06.27
MG5233 X-Band Magnetron  (0) 2012.06.27
MG5241F X-Band Magnetron  (0) 2012.06.27
MG5245 X-Band Magnetron  (0) 2012.06.26
MG5273 X-Band Magnetron  (0) 2012.06.26

댓글