본문 바로가기

E2V/Magnetron48

MG5255 X-Band Magnetron ABRIDGED DATA rugged, lightweight, fixed frequency pulse magnetron, Operating frequency 9410 ± 30 MHz Typical peak output power 6.0 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 0.7 kg approx Heater current at 6.3V 0.5 A Mounting po.. 2012. 6. 26.
MG5256 X-Band Magnetron ABRIDGED DATA rugged, lightweight, fixed frequency pulse magnetron, Operating frequency 9375 ± 30 MHz Typical peak output power 12.5 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 0.7 kg approx Heater current at 6.3V 0.5 A Mounting p.. 2012. 6. 26.
MG5257 X-Band Magnetron ABRIDGED DATA rugged, lightweight, fixed frequency pulse magnetron, electically and mechanically interchangeable with 2J42 and M503A. Operating frequency 9410 ± 30 MHz Typical peak output power 12.5 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3.. 2012. 6. 26.
MG5388C X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetron Operating frequency 9410 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 500 g approx Heater current at 6.3V 0.55 A Mounting position any Cathode pre-heating time (minimu.. 2012. 6. 25.
MG5388 X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetron Operating frequency 9410 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 500 g approx Heater current at 6.3V 0.5 A Mounting position any Cathode pre-heating time (minimum.. 2012. 6. 25.
MG5243 X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetron Operating frequency 9445 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 0.7 kg approx Heater current at 6.3V 0.5 A Mou.. 2012. 6. 25.
MG5251 X-Band Magnetron ABRIDGED DATA Lightweight, fixed frequency pulse magnetron. It is electrically and mechanically interchangeable with M5196F. Operating frequency 9410 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweig.. 2012. 6. 25.
MG5238A X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetrons differing only in cold impedance and heater / cathode connections. the MG5238A and MG5238B are electrically and mechanically interchangeable with the M5196A and M5196B respectively. Operating frequency 9445 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupl.. 2012. 6. 19.
MG5353 X-Band Magnetron TYPICAL OPERATION Heater voltage Min Typical Max - 6.3 - V Heater current - 0.6 - A Pulse duration - 0.9 - ms Pulse repetition rate - 1000 - pps Peak anode voltage - 1.9 - kV Peak anode current - 2.0 - A Peak output power 1.2 1.5 - kW Mean output power 0.6 0.75 - W RF bandwidth - 2.4 - MHz Sidelobe amplitude - -9 - dB Frequency 9380 - 9440 MHz Missing pulses - - 0.01 % MECHANICAL Overall dimensi.. 2012. 6. 19.