radar parts21 MG5459 X-Band Magnetron GENERAL DATA Electrical Mechanical Operating frequency 9375 ±30 MHz Overall dimensions see Outline Typical peak output power 25 kW Net weight 0.7 kg approx Cathode indirectly heated Mounting position any Heater voltage (see note 1) 6.3 V Coupler IEC UBR100 Heater current at 6.3V (see note 2) 0.5 A Cooling natural Cathode pre-heating time (minimum) (see note3) 60 s Output no.16 waveguide Input ca.. 2012. 6. 28. MG5437 X-Band Magnetron GENERAL DATA Electrical Mechanical Operating frequency 9410 ±30 MHz Overall dimensions see Outline Typical peak output power 25 kW Net weight 0.7 kg approx Cathode indirectly heated Mounting position any Heater voltage (see note 1) 6.3 V Coupler IEC UBR100 Heater current at 6.3V (see note 2) 0.5 A Cooling natural Cathode pre-heating time (minimum) (see note3) 60 s Output no.16 waveguide Input ca.. 2012. 6. 28. MG5424 X-Band Magnetron GENERAL DATA Electrical Mechanical Operating frequency 9410 ±30 MHz Overall dimensions see Outline Typical peak output power 25 kW Net weight 0.7 kg approx Cathode indirectly heated Mounting position any Heater voltage (see note 1) 6.3 V Coupler IEC UBR100 Heater current at 6.3V (see note 2) 0.5 A Cooling natural Cathode pre-heating time (minimum) (see note3) 60 s Output no.16 waveguide (22.86 *.. 2012. 6. 28. MG5271 X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetron, Operating frequency 9375 ± 30 MHz Typical peak output power 25 kW Magnet integral Out put No.16 waveguide Coupler IEC UBR100 Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 0.7 kg approx Heater current at 6.3V 0.5 A Mounting position any Cathode .. 2012. 6. 28. MG5265 X-Band Magnetron ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency 9475 ± 20 MHz Typical peak output power 30 kW Output no.16 waveguide (22.86 x 10.16 mm internal) Magnet integral Coupler UG-40B/U (NATO S.N. 5985-99-083-0051) Electrical Cathode indirectly heated Heater voltage (see note 1) 6.3 V Heater current at 6.3V 0.55 A Cathode pre-heating time (minimum)(see note 2) 60 s Heater starting cur.. 2012. 6. 28. MG5264 X-Band Magnetron ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency 9410 ± 30 MHz Typical peak output power 25 kW Magnet integral Out put No.16 waveguide (22.86 x 10.16 mm internal) Coupler UG-40B/U (NATO S.N. 5985-99-083-0051) Electrical Mechanical Cathode indirectly heated Overall dimensions see outline Heater voltage (see note 1) 6.3 V Netweight 1.5 kg approx Heater current at 6.3V 0.55 A Moun.. 2012. 6. 28. MG5242T X-Band Magnetron ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency 9410± 30 MHz Typical peak output power 25 kW Output no.16 waveguide (22.86 x 10.16 mm internal) Magnet integral Coupler UG-40B/U (NATO S.N. 5985-99-083-0051) Electrical Cathode indirectly heated Heater voltage (see note 1) 6.3 V Heater current at 6.3V 0.55 A Cathode pre-heating time (minimum)(see note 2) 60 s Heater starting curr.. 2012. 6. 28. RF Receivers Parts List(RF 리시버) E2V Part No. Frequency (MHz) MDS (dBm typical) Noise figure (dB max) Power supplies B3IM16161 9.3 - 9.5 -100 4.7 +15, +5, -15 4 bandwidths, perfomance monitoring, AFC B3IM16171 9.1 - 9.3 -100 4.7 +15, +5, -5.2 Frequency variant of B3IM1616 2011. 8. 16. Noise generators Parts List(노이즈 제너레이터) E2V Part No. Frequency (MHz) ENR (dB max) Incident power pulsed, 1µs (kW max) Power supplies B3NG1639 8.8 - 9 15 60 +21 V, 0 - 25 mA Waveguide (WG16) cal. frequency 8900 GHz B3NG1641 9.3 - 9.5 15 60 +21 V, 0 - 25 mA Waveguide (WG16), cal. frequency 9.375 GHz B3NG1642 9.3 - 9.5 15 60 +21 V, 0 - 25 mA Waveguide (WG16), cal. frequency 9.410 GHz B3NG1004 3000 - 3100 15 60 +24 V, 0 - 30 mA Waveguide .. 2011. 8. 16. 이전 1 2 3 다음