모든 포스팅 보기224

M1437A X-Band Magnetron GENERAL DATA Electrical Heater Voltage(Preheat) Min Typical Max Unit 5.7 6.3 6.9 V Heater Voltage(Operation) - 3.7(note 1) - V Preheat time 120 - - S Peak anode voltage 7.5 8.0 8.5 kV Rate of rise of voltage pulse - 70 100 kV/μs Peak anode current 6.0 8.0 10.0 A Mean anode current 6.0 8.0 10.0 mA Peak anode input power - - 75 kW Mean anode input power - - 85 W Pulse duration (Ditected R.F) 0.05 .. 2012. 6. 19.
MG5238A X-Band Magnetron ABRIDGED DATA Compact, rugged, lightweight, fixed frequency pulse magnetrons differing only in cold impedance and heater / cathode connections. the MG5238A and MG5238B are electrically and mechanically interchangeable with the M5196A and M5196B respectively. Operating frequency 9445 ± 30 MHz Typical peak output power 4.0 kW Magnet integral Out put No.16 waveguide(0.900x0.400 inch internal) Coupl.. 2012. 6. 19.
MG5353 X-Band Magnetron TYPICAL OPERATION Heater voltage Min Typical Max - 6.3 - V Heater current - 0.6 - A Pulse duration - 0.9 - ms Pulse repetition rate - 1000 - pps Peak anode voltage - 1.9 - kV Peak anode current - 2.0 - A Peak output power 1.2 1.5 - kW Mean output power 0.6 0.75 - W RF bandwidth - 2.4 - MHz Sidelobe amplitude - -9 - dB Frequency 9380 - 9440 MHz Missing pulses - - 0.01 % MECHANICAL Overall dimensi.. 2012. 6. 19.
MG5223 S-Band Magnetron ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency 3050 ± 10 MHz Typical peak output power 30 kW Magnet integral Coupler mates with NATO S.N. 5985-99-083-0058 Electrical Cathode indirectly heated Heater voltage (see note 1) 6.3 V Heater current at 6.3V 1.25 A Cathode pre-heating time (minimum) 180 s Heater starting current, peak value, not to be exceeded 6.0 A max Mechanical Over.. 2012. 6. 19.
CX1551 Thyratron ABRIDGED DATA Deuterium-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition rates, in parallel for switching higher powers, or for switching long pulses. A reservoir operating from the cathode heater supply is incorporated. The tube is flange mounted with flexible lead connections. Peak output power 16.5 MW max Peak forward ano.. 2012. 6. 15.
CX1154 Ceramic Thyratron ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for switching high power at high pulse repetition rates or for switching long pulses. A reservoir operating from a separate heater supply is incorporated. Peak forward anode voltage 40 kVmax Peak anode current 3.0 kA max Average anode current 2.0 A max Electrical Ca.. 2012. 6. 15.
MG5223F S-Band Magnetron ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency 3050 ± 10 MHz Typical peak output power 30 kW Magnet integral Coupler mates with NATO S.N. 5985-99-083-0058 Electrical Cathode indirectly heated Heater voltage (see note 1) 6.3 V Heater current at 6.3V 1.25 A Cathode pre-heating time (minimum) 180 s Heater starting current, peak value, not to be exceeded 6.0 A max Mechanical Over.. 2012. 6. 15.
NBB-441 SART Battery GENENAL DATA Product NBB-441 SAB-300 Description 2 cell shrink wrap Original Supplier JRC Taiyo-Musen Hazardous Yes Sart Type JQX-30A TBR-600 Comments SPECIFICATIONS Nominal voltage : 6V Nominal capacity : 10AH Battery type : Lithium-Manganese Dioxide Battery Shelf life : 5 years or more Weight Approx. 200g 2012. 6. 15.
RESCURE SART Battery GENENAL DATA Product Rescuer battery Description Original Supplier Sartech Hazardous Yes Sart Type Various Type Comments Do not recharge Do not incinerate Do not short-circuit SPECIFICATIONS Nominal voltage : 7.2 V Nominal capacity : 10 Ah Battery type : Lithium Battery Shelf life : 5 years or more Weight Approx. 200g 2012. 6. 15.